Main Article Content
Abstract
Mortar is a mixture of adhesives (portland and lime cement), sand and water with certain compositions. Use of adhesive materials on building construction in general still use portland cement, but in terms of portland cement costs are required a greater cost. This study aims to determine the behavior of the compressive strength of mortar using Coconut Shell Charcoal (CCS) as a substitute for cement. The method of manufacture and testing of mortar compressive strength refers to SNI 03-6825-2002 with mortar 1Pc: 3Ps mortar. Range of initial flow values used is 105% - 115%. CCS used is pass No. 200 which utilizes combustion results from coconut shells. Variations of mortar test specimens were 0%, 2.5%, 5%, 7.5%, 10% and 12.5% respectively each variation had 10 sample specimens. Test sample was immersed for 27 days and compressive strength mortar test was performed at 28 days. Value compressive strength of mortar on variations of 0%, 2.5%, 5%, 7.5%, 10%, 12.5% are 25.11 MPa, 25.65 MPa, 26.07 MPa,27.00 MPa, 26.40 MPa and 25.98 MPa. The highest increase of mortar compressive value was variation of 7.5% by 7.51%.
Article Details
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
- This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
References
- ASTM C 270: Standard Specification for Mortar for Unit Masonry. American Standard Testing and Material.
- Moerdwiyono, 1998, Diktat Teknologi Bahan. Semarang.
- SNI 03-6225-2002: Metode Pengujian Kuat Tekan Mortar Semen Portland untuk Pekerjaan Sipil. Depertemen Pekerjaan Umum.
- SNI 03-6820-2002: Spesifikasi Agregat Halus untuk Pekerjaan Adukan dan Plesteran dengan Bahan Dasar Semen. Depertemen Pekerjaan Umum.
- SNI 03-6825-2002: Metode Pengujian Kekuatan Tekan Mortar Semen. Depertemen Pekerjaan Umum.
- SNI 03-6882-2002: Spesifikasi Campuran Mortar. Depertemen Pekerjaaan Umum.
- SNI S-04-1989-F: Persyaratan Air dalam Campuran beton dan Mortar.
- Depertemen Pekerjaan Umum.
- Sutikno, 2003, Pengaruh Penggunaan Abu Hasil Pembakaran Kayu pada Kuat Tekan Mortar, UNESA.
- Wardi, 2003, Pengaruh Pemakaian Arang Batok Kelapa terhadap Kuat Tekan Beton. Jurnal R & B, 3(1) PP. 27-34 ISSN 1412-5080 http://www.polinpdg.ac.id.
- Zahrina, I., 2007, Pemanfaatan Abu Sabut dan Cangkang Sawit sebagai Sumber Silika pada Sintesis ZSM-5. 31. Jurnal sains dan teknologi, 2007-academia.edu.
References
ASTM C 270: Standard Specification for Mortar for Unit Masonry. American Standard Testing and Material.
Moerdwiyono, 1998, Diktat Teknologi Bahan. Semarang.
SNI 03-6225-2002: Metode Pengujian Kuat Tekan Mortar Semen Portland untuk Pekerjaan Sipil. Depertemen Pekerjaan Umum.
SNI 03-6820-2002: Spesifikasi Agregat Halus untuk Pekerjaan Adukan dan Plesteran dengan Bahan Dasar Semen. Depertemen Pekerjaan Umum.
SNI 03-6825-2002: Metode Pengujian Kekuatan Tekan Mortar Semen. Depertemen Pekerjaan Umum.
SNI 03-6882-2002: Spesifikasi Campuran Mortar. Depertemen Pekerjaaan Umum.
SNI S-04-1989-F: Persyaratan Air dalam Campuran beton dan Mortar.
Depertemen Pekerjaan Umum.
Sutikno, 2003, Pengaruh Penggunaan Abu Hasil Pembakaran Kayu pada Kuat Tekan Mortar, UNESA.
Wardi, 2003, Pengaruh Pemakaian Arang Batok Kelapa terhadap Kuat Tekan Beton. Jurnal R & B, 3(1) PP. 27-34 ISSN 1412-5080 http://www.polinpdg.ac.id.
Zahrina, I., 2007, Pemanfaatan Abu Sabut dan Cangkang Sawit sebagai Sumber Silika pada Sintesis ZSM-5. 31. Jurnal sains dan teknologi, 2007-academia.edu.