Main Article Content

Abstract

The power transformer is a high voltage equipment that functions as a distributor of electric power from high voltage to low voltage or from low voltage to high voltage. If the transformer's isolation condition deteriorates, it can have an impact on operating failure and the most fatal is that the transformer is damaged which can cause electrical system disturbances. To overcome this it is necessary to test the insulation resistance. This test is carried out using the polarization index method to determine the feasibility of the insulation resistance in the transformer. The use of this method is the most accurate and effective way to determine the feasibility of insulation resistance in transformers at distribution substations in Indonesia. This study took data at the location of PT. PLN (Persero) UP3 Bengkulu. In the insulation resistance test, the polarity index measurement results are obtained. Based on the data that has been collected then proceed with calculations and analysis to obtain better results. The ground-primary polarization index value shows that it is in good condition with a primary-ground value of 1.25 and a secondary-ground polarization index value of 1.5 (good standard between 1.25 – 2.0).

Keywords

Insulation, Polarization Index, Insulation Resistance Testing,

Article Details

How to Cite
Indra, M. H., Yanolanda Suzantry Handayani, & Priyadi, I. (2022). Pengujian Tahanan Isolasi Pada Transformator Distribusi 160 kVA Di PT. PLN (PERSERO) UP3 Bengkulu. JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER, 12(2), 8–15. https://doi.org/10.33369/jamplifier.v12i2.25274

References

  1. M. F. Robbani, D. Nugroho, and G. Gunawan, “Penentuan Kelayakan Tahanan Isolasi Pada Transformator 60 MVA Di Gardu Induk 150 kV Tegal Dengan Menggunakan Indeks Polarisasi, Tangen Delta, Dan Breakdown Voltage,” Elektrika, vol. 12, no. 2, p. 60, 2020, doi: 10.26623/elektrika.v12i2.2721.
  2. A. M. Suganda, “Analisa Kualitas Tahanan Isolasi Transformator Daya,” Sinusoida Vol. XXIII No. 2 , Desember 2021, vol. XXIII, no. 2, pp. 1–10, 2021.
  3. S. Manjang, I. Kitta, S. -, Y. -, I. C. Gunadin, and G. -, “Pelatihan Pemeliharaan Sistem Distribusi Tenaga Listrik pada Tenaga Kerja Perusahaan Bidang Ketenagalistrikan,” J. TEPAT Appl. Technol. J. Community Engagem. Serv., vol. 2, no. 2, pp. 45–50, 2019, doi: 10.25042/jurnal_tepat.v2i2.98.
  4. Wiwin A Oktaviani, Taufik Barlian, and Marami Ahmad Gazani, “Pengujian Isolasi Trafo Daya 30 MVA pada GI Sungai Juaro Palembang dengan Indeks Polaritas dan Tangen Delta,” J. Rekayasa Elektro Sriwij., vol. 3, no. 1, pp. 199–204, 2021, doi: 10.36706/jres.v3i1.43.
  5. H. L. Latupeirissa, “Analisa Umur Pakai Transformator Distribusi 20 KV,” J. Simetrik, vol. 8, no. 2, pp. 139–144, 2018.
  6. Y. P. Tondok, L. S. Patras, and F. Lisi, “Perencanaan Transformator Distribusi 125 kVA,” J. Tek. Elektro dan Komput. Vol.8, vol. 8, no. 2, pp. 83–92, 2019.
  7. diki candra Gunawan and Jamaaluddin, “Transformator listrik,” pp. 2–5, 2020, [Online]. Available: http://eprints.umsida.ac.id/7330/1/PS_4B1_020_DIKI CANDRA GUNAWAN.pdf
  8. P. Seminar, N. Nciet, and N. Conference, “ANALISA TAHANAN ISOLASI TRANSFORMATOR 3 DI PT. PLN (Persero) GARDU INDUK 150 KV Pati,” Pros. Semin. Nas. NCIET, vol. 1, no. 1, pp. 141–149, 2020, doi: 10.32497/nciet.v1i1.72.
  9. U. Situmeang, B. Mulyanto, and M. Putra Halilintar, “Transformator Daya 125 Mva Menggunakan Indeks Polarisasi Tangen Delta Dan Breakdown Voltage Di Pltu Tenayan Raya 2 X 110 Mw,” Jte Uniba, vol. 6, no. 2, p. 206, 2022.