Main Article Content

Abstract

Cigarette smoke is a source of air pollution, especially indoors. The smoke from burning cigarettes doesn't just evaporate into the air, but there is nicotine residue that sticks to the dust or items around the smoker, such as clothes, carpets, walls. A smoke filter or smoke particulate filter is something that is really needed to reduce pollutants in the room. Research on "Testing Electrostatic Precipitator (ESP) Cigarette Smoke Particulate Filters with Copper and Aluminum Electrodes" aims to analyze the comparison of the use of copper and aluminum electrodes as filters on ESP. In this research, a high voltage DC generator was used using the full-wave cascade method, for the high voltage that was successfully generated by this full-wave cascade method was 2.25 kV to 5.46 kV. From the test results, it was found that the difference in ( levels between the inlet and outlet containers ( using a copper plate was higher than using an aluminum plate. In addition, it can be concluded that increasing the voltage causes more ( levels to be filtered.

Keywords

Electronic Precipitator Filter partikulat Kaskade Full Wave

Article Details

How to Cite
Anggraini, I. N., Elita Amrina, Afriyastuti Herawati, Raydian Rafflecio Andromeda, & Yuli Rodiah. (2023). PENGUJIAN FILTER PARTIKULAT ASAP ROKOK ELECTROSTATIC PRECIPITATOR DENGAN ELEKTRODA TEMBAGA DAN ALUMUNIUM. JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER, 13(2), 84–90. https://doi.org/10.33369/jamplifier.v13i2.28056

References

  1. Wilers, Stefan, dkk, 2005. “Enviromental Tobacco Smoke (ETS) Exposure in Children with Asthma-Relation Between Lead and Cadmium, and Continine Concentrations in Urine. Sweden: Departemen of Occuputional and Enviromental Medicine.
  2. Adam, Masuli Ibnu, 2018. “Rancang Bangun Perangkap Nyamuk Menggunakan Metode Cokroft-Walton Berbasis Tegangan Tinggi”. Fakultas Teknologi Industri, Universitas Islam Indonesia, Yogyakarta.
  3. Ginting, Nofita Sari Br, dkk, 2018. “Perancangan Pembangkit Tegangan Tinggi DC Dengan Metode Cokroft-Walton Tipe Fullwave”. Dalam TRANSIENT, ISSN:2302-9929,443 (Vol.2, Juni 2018). Semarang: UNDIP
  4. Nauwir, Herman, dkk, 2018. “Modifikasi Prototype Filter Pengendap Debu Elektrostatik Dengan Model Vertikal Menggunakan Tegangan Tinggi DC”. Daam SNP2M pp. 224-227. Makassar: Politeknik Negeri Ujung Pandang
  5. Badan Pengendalian Dampak Lingkungan Hidup. 1977. “Indeks Kualitas Udara”.
  6. Lillieblad, Lena, dkk, 2006. “Electrostatic Precipitator Performance With Chinese Coals”. Dalam ICESP X. Swede: ALSTOM Power Sweden AB.
  7. Fitrianto, Ardy, 2018. “Analisa Kinerja Electrostatic Precipitator (ESP) Berdasarkan Hasil Perubahan Emisi Pada Power Boiler Pembangkit Listrik Tenaga Uap”. Fakultas Teknologi Informasi dan Elektro, Universitas Teknologi Yogyakarta, Yogyakarta.